Intruder alarms and hold up systems are security systems designed to protect property and people from unauthorised access, theft, and robbery. Additionally, intruder alarms are designed to detect unauthorised entry into a property or area. Both intruder alarms and hold up systems are important tools for protecting people and property from crime. They can provide peace of mind for business owners, and can help deter criminals from attempting to break in or commit robbery.

Intruder and Hold Up Alarm System Standards

BS EN 50131-1

BS EN 50131-1:2018+A3:2020 is one of the main three European standards. For this reason, these standards outline the performance requirements for intrusion and hold-up alarm systems (I&HAS) installed in buildings. In fact, the standard includes four security grades and four environmental classes. Utilising these grades, we can assist manufacturers, installers, purchasers, and procurers in ensuring that the alarm system is appropriate and meets risk assessment criteria. The purpose of the standard is to enhance the security of supervised premises through the use of I&HAS.

BS8243

BS 8243:2021 is a code of practice. In brief, this practice provides guidelines for the design, installation, and configuration of intruder and hold-up alarm systems. Using these, we can emulate the perfect alarm conditions.

PD6662

PD6662 is a UK industry standard that outlines guidelines for the installation, commissioning, and maintenance of intruder and hold-up alarm systems. In effect, the standard provides a framework for compliance with European standards. This ensures that alarm systems are installed and maintained in a consistent and reliable manner.

PD6662 covers a range of topics including alarm types, system design, installation, and maintenance requirements. Therefore, by adhering to the guidelines set out in PD6662, alarm installers and users can be confident that their system is fit for purpose and provides an effective security solution.

Orisec Intruder Alarms

What Are The Intruder Alarm System Grades?

According to the EN standard, it’s not mandatory to use the same grade of components in all parts of an intruder alarm system.

ALSO: If the installation is a Grade 2, it is acceptable to use a Grade 3 power supply. However, if an installer fits a Grade 2 component, such as a detector, into a system, the system’s overall rating is limited to Grade 2 at best.

Low Risk – Grade 1

Grade 1 Intruder Alarms are recommended for properties with a low risk of theft. Typically, this is where the likelihood of intruders targeting the premises is minimal. In reality, the assumption is that any potential intruders are likely to be opportunistic rather than pre-planned. The application guide for Grade 1 Intruder Alarms is based on the assumption that intruders will attempt to gain entry through basic methods. For example, breaking open a door.

A Grade 1 Intruder Alarm is typically only suitable for residential properties without an insurance requirement for an alarm system.

Low/Medium Risk (Popular) – Grade 2

Grade 2 Intruder Alarms are suitable for properties at a slightly higher risk of theft. In general, these are areas where there may be items of interest to experienced thieves. In such cases, intruders are expected to have some knowledge of alarm systems. Thus, these intruders may carry tools to bypass a simple alarm. They are also likely to survey the building for easy access points such as doors, windows, and other openings.

Grade 2 Intruder Alarms are suitable for most residential properties and low to medium risk commercial establishments.

Medium/High Risk – Grade 3

Grade 3 Intruder Alarms are recommended for properties at significant risk of theft. Often, these are buildings where valuable items may be present. Therefore, it is likely that intruders will attempt to gain entry by forcing doors, windows, or other access points. Also, these people are highly experienced in dealing with alarm systems and equipped with specialised tools and equipment to bypass the system.

Grade 3 Intruder Alarms are recommended for high-risk residential and most commercial properties, including busy retail shops.

High Risk – Grade 4

Grade 4 intruder alarms are designed for properties at very high risk of break-ins. Areas where burglars are expected to have the skills and tools to modify parts of the alarm system to avoid detection. Unlike Class 3, the intruders are likely to gain entry by penetrating walls, ceilings, or floors, and are unlikely to act alone.

Grade 4 Intruder Alarms are recommended for extremely high-risk residential and higher-risk commercial properties, such as banks or bullion stores.

What Does An Intruder & Hold Up Alarm Consist Of?

An intruder alarm system, also known as a burglar alarm, consists of:

  • Control Panel (CIE).
  • Keypad (ACE).
  • Expander (RIO, ZEM, LIM, ZEX).
  • Sounder (WD).
  • Detector (options include PIR, Dual Tech, Glass Break, Active Beam, Panic Button).
  • Hold Up Device (HD).
  • Proximity Fob (Digital Key).
  • Signalling Device (if monitored).
  • Ancillaries (gas detector, smoke detector, flood detector and smoke cloak).

Please ensure you stick with the same brand throughout your system as some components will NOT be compatible. OHEAP recommends Orisec.

Orisec Keypad

Orisec Panel - intruder & hold up alarm systems

Dual Tech PIR

PIR Sensor - intruder & hold up alarm systems

Internal Sounder

intruder & hold up alarm systems Sounder

Keyfobs

keyfobs

Expander

Expander Orisec

What Are The Intruder Alarm System Classifications?

 

Indoor – Class 1

Indoor environmental factors are typically consistent. The temperature is well-regulated within a residential or commercial property and the temperature can range from +5°C to +40°C.

Outdoor Sheltered OR Indoor Extreme Conditions – Class 3

Class 3 systems are those exposed to extreme indoor conditions or in sheltered outdoor areas. Typically, components are partially exposed to the elements or the components are indoors, however, the temperature is ranging from -25°C to +50°C.

Indoor – Class 2 (Popular)

Typically, exposed to indoor environmental factors and is an area affected by temperature fluctuations. Often this will occur in spaces such as corridors, halls, staircases, and areas with windows that experience condensation. Also, we experience these in unheated storage areas or intermittent warehouses. The temperatures can range from -10°C to +40°C.

Outdoor, External and Fully Exposed – Class 4

If the intruder alarm components are completely exposed to the weather, you will need Class 4. Typically, you won’t need this system unless your components are subjected to environmental temperature fluctuations that range from -25°C to +60°C.

Related Guides

Dry Riser System | A Complete Guide

Dry Riser System | A Complete Guide

A dry riser system ensures fire safety in large buildings. In this comprehensive guide, we will delve into what dry risers are, how they function and the legal requirements surrounding them. We will also explore the potential consequences of neglecting dry riser...

Fire Safety | Entertainment Venues | A Complete Guide

Fire Safety | Entertainment Venues | A Complete Guide

Event fire safety is vital, especially within entertainment venues. This guide to event fire safety for entertainment venues will outline fire safety risks and provide information on how to keep entertainment venues safe.Event Fire Safety, Fire Risk Assessments Fire...

Fire Risk Assessments | UK Landlords | A Complete Guide

Fire Risk Assessments | UK Landlords | A Complete Guide

As a landlord, you must ensure the safety of your tenants. Part of this responsibility includes conducting fire risk assessments. Fire safety is a critical aspect of property management and understanding the requirements and responsibilities can help protect your...

Security | Office Buildings | A Complete Guide

Security | Office Buildings | A Complete Guide

Organisations need to implement security measures to protect their assets, employees and sensitive information. A workplace can be subject to a variety of threats, ranging from physical intrusions to digital breaches. It is extremely important to safeguard against...

Fire Extinguisher Servicing | A Complete Guide

Fire Extinguisher Servicing | A Complete Guide

In the world of fire safety, fire extinguishers are a key component. We must include them in our fire protection strategies. These pieces of kit are often the first line of defence in the event of a fire. Their portability, mixed with swift deployment can save the...

Security Systems For Your Business | A Complete Guide

Security Systems For Your Business | A Complete Guide

Running a modern business involves finding solutions to a wide range of extremely complex problems. There are few circumstances where this is truer than in security. Keeping your business protected and securing your premises should always be a top priority.  However,...

Protect From Asbestos | A Complete Guide

Protect From Asbestos | A Complete Guide

Do you know how to protect yourself from asbestos? Asbestos is responsible for more than 5000 workplace deaths a year. Although it was completely banned in 1999, many buildings in Great Britain that were built or refurbished before 2000 may contain asbestos. But you...

Keep Your Small Paying Guest Accommodation Safe From Fire

Keep Your Small Paying Guest Accommodation Safe From Fire

On October 1st 2023, the UK government released a new comprehensive guide titled "Ensuring Safety in Your Small Paying Guest Accommodation". This was produced in collaboration with experts from the fire, commercial and housing sectors. The new fire safety legislation...

Fire Safety Legislation | A Complete Guide

Fire Safety Legislation | A Complete Guide

Fire safety is a critical aspect of protecting lives. In short, we must avoid the devastating effects of a fire. For this reason many governments mitigate fire risks by implementing comprehensive fire safety legislation. However, navigating through the complex web of...